Place the gas cylinder outside the sauna room or sauna tent, away from all heat sources. Never place the gas cylinder inside the sauna or near the heater, fireplace, open flame, or any other heat source.
Use a gas hose with an 8–10 mm internal diameter and a maximum length of 1200–1500 mm, securely fixed with hose clamps at both ends.
Keep the gas hose free from kinks, tension, and mechanical stress, and fully visible and accessible for inspection.
Use only certified low-pressure gas regulators and ensure that the regulator pressure matches the heater appliance category.
Do not use LPG cylinders larger than 25 kg.
Always close the gas cylinder valve and pressure regulator valve when the heater is not in use.
A gas cylinder may supply only one appliance, and the pressure regulator must be connected directly to the gas cylinder valve.
Appliance gas pressure versions: I3B/P: 30 mbar (butane, propane, or their mixtures) and I3P: 37 mbar (propane).
Use only certified LPG hoses, fittings, and connections. FinSteam recommends using a stainless steel braided gas hose for maximum durability and heat resistance.